             Wood flooring adhesive products help with A* refurbishment at Staffordshire school


               BALL AND CO’s Styccobond B95 high   a waterproof surface membrane where   had cured, another layer of Stopgap 1200
            F  performance wood flooring adhesive   a moisture management solution is   was applied to create a perfectly smooth
            has been used to install new oak blocks   required to stop the adverse effects of   base for the receipt of new wooden
            over an area of 195 sq m, as part of the   excess subfloor moisture on subsequently   floorcoverings. If the product is applied to
            refurbishment of the floor of a school   installed floorcoverings.      Stopgap waterproof surface membranes
            hall at Alleyne’s Academy, in Stone,   ‘Once the repairs to the subfloor were   within 24 hours of the membrane curing,
            Staffordshire after it was damaged by   complete, contractors applied F Ball’s   there is no need to prime the surface
            floods.                             Stopgap P131 general-purpose primer,   beforehand.
              Says F Ball: ‘Fast-track products,   diluted with seven parts of water to every   ‘Contractors went over the smoothing
            including the company’s Stopgap 1200   one part of primer, over the subfloor.   compound with an F Ball spiked roller to
            smoothing compound, enabled the work   Once the primer was dry, Stopgap 1200   dispel any trapped air to avoid pinholing
            to take place during the exam season   smoothing compound was applied at a   occurring.’
            without disruption to students.     thickness of about 5mm over the primed   The company adds: ‘When the
              ‘Contractors from Basford-based B&P   subfloor.’                      smoothing compound had cured,
            Flooring first carefully prepared the   Before the project began, it was   contractors used F Ball’s Styccobond B95
            subfloor to optimise the appearance   determined moisture levels in the subfloor   high performance wood flooring adhesive
            and performance of the newly-installed   exceeded the maximum threshold for   to install new oak blocks over the entire
            flooring, beginning by removing existing   installing wood floorcoverings, which are   floor area in a herringbone pattern.
                                                                                    Styccobond B95 is a one-part, flexible,
            wooden blocks from the floor and used   particularly susceptible to damage from
            a mechanical scabbler to remove old   moisture.                         moisture-curing adhesive for installing
                                                                                    a wide range of wood floorcoverings. It
            adhesive residues left behind.        Where subfloor relative humidity levels   is designed to accommodate the natural
              ‘Lifting the wooden blocks resulted in   exceed 65% relative humidity (RH) and
            minor damage to the building’s existing   wood floorcoverings are to be installed,   movement of wood over the lifetime
                                                                                    of the floorcoverings, solvent and
            concrete screed, causing holes up to   a moisture management solution is   isocyanate-free, quick to develop a high
            25mm deep to appear. These were     essential to stop excess subfloor moisture   bond strength and provides good grab,
            repaired using F Ball’s Stopgap 1200   attacking adhesives and damaging   an advantage for contractors creating the
            smoothing compound mixed with Stopgap   floorcoverings, potentially resulting in   parquet design.’
            graded aggregate.’                  complete floor failure.               Commenting on the project, managing
              Continues the company: ‘Stopgap     For this reason, contractors applied F   director of B&P Flooring Mark Stevenson
            1200 is a fast setting, fast drying two-  Ball’s Stopgap F77 one-part waterproof   said: ‘Using Stopgap 1200 allowed us to
            component smoothing compound, which   surface membrane to create a barrier to   complete the project to a high standard,
            can be used directly over old adhesive   impede the passage of excess subfloor   quickly, meaning no work was ongoing
            residues, in which case there is no need   moisture to the level of the floorcoverings.  while the students were taking their
            to prime beforehand. It can also be filled   ‘Stopgap F77 allows a barrier against   exams.’ 
            up to 30mm to repair damaged subfloors   moisture values of up to 98% RH to be   www.f-ball.co.uk
            when mixed with aggregate.          created with a single coat application in as
              ‘The smoothing compound is moisture   little as three hours,’ says F Ball.  Go online and visit the SHOWCASE PORTAL
            resistant, allowing it to be applied before   ‘After the waterproof surface membrane   to read more from F.Ball & Co