SECTOR FOCUS SUBFLOORS & SCREEDS




                                                                                           Rapid RH L6 in-situ probes fully comply
                                                                                                  with ASTM 2170 standards


































              for surface moisture testing if that is   drying from one side (20% depth is best   Integrating Rapid RH and C555 for
              approved by the flooring manufacturer.  if drying from two sides).    comprehensive moisture assessment
                The C555 is the only concrete moisture   •  Use a wire brush, vacuum, and   With the C555’s surface moisture
              meter in the market that allows for in-  attachment to clean out holes.  readings and the Rapid RH’s deeper
              field calibration. It provides a preliminary   •  Place the needed amount of sensors,   readings, you’ll have a more thorough
              evaluation of comparative moisture   targeting areas with the highest surface   understanding of moisture distribution
              conditions of concrete, gypsum cement,   moisture readings.           throughout the depth of the slab.
              or other floor slabs and screeds. And   •  Place at least three sensors for the first   Let’s say you have a flooring project
              it’s twice as accurate as other leading   1,000 sq ft. and one more per additional   with a customer and you scan the
              moisture meter brands, according to   1,000 sq ft.                    concrete subfloor with the C555 to
              recent tests.                      Using the C555 for surface testing  identify potential moisture issues. There
                With the C555 and Rapid RH probes,   •  Use the C555 on flat surfaces for full   are some higher moisture readings near
              you simply scan the concrete slab with   sensor contact in smooth areas   one of the walls so, you need more
              the C555, detect areas with higher   •  Set up the C555's alarm to get notified   comprehensive data before installation.
              surface moisture readings, and insert in-  if moisture levels exceed set thresholds,   You install Rapid RH smart sensors at
              situ probes in those areas.         adjustable from 0.0% to 6.9%      40% depth throughout the slab and let
                The C555 is also a great non-    •  If you’re ever unsure if the C555 is   the sensors equilibrate for 24 hours.
              destructive option in situations when this   calibrated, use the included calibrator   Once equilibrated, most of the RH
              type of measurement is accepted and it   platform to calibrate the C555 back to   readings are under the required 75% (or
              comes in handy for areas where drilling is   original factory standards.  whatever the floor covering manufacturer
              undesirable, such as with in-floor heating                            specifies), but they’re showing higher
              installations.                     Testing for in-floor heating installation  readings near the wall, which is above the
              Best practices for concrete moisture   Testing moisture for in-floor heating   flooring manufacturer requirements (and will
                                                 systems takes a bit more care. Flooring
              testing                            installers often avoid drilling into heated   likely invalidate the warranty for not meeting
              For the most accurate readings, follow   subfloors to prevent damaging the   required pre-installation conditions).
              these best practices.              embedded heating system. Piercing the   But because you used the right tools
              Pre-test preparation               electrical cables or heating coils can lead   at the right time, you prevented a future
                                                                                    flooring failure.
              Clean the concrete surface to remove   to expensive repairs or even electrical   So as you prepare for each new flooring
              debris and contaminants where moisture   hazards.                     project, remember to always adhere to
              meter measurements are to be done.  Before installing Rapid RH probes, use   ASTM testing standards and flooring
                � Maintain stable temperatures in the   a thermal camera to locate heating coils   manufacturer guidelines to avoid flooring
              environment for ideal moisture testing   and find the best place to drill.   failures. And take extra care when dealing
              conditions.                         And when appropriate, using the C555   with in-floor heating system. 
              Using Rapid RH for in-depth testing  to scan for moisture can be a great, non-  www.wagnermeters.com
              •  Use a hammer drill and masonry drill bit   invasive alternative in situations when     Jason Spangler is Wagner Meters’ sales
                to drill holes at 40% depth in concrete, if   this type of testing by itself is acceptable.  manager

         80  CFJ April 2026                                                                       www.contractflooringjournal.co.uk